Two industrial battery systems, compared from the data sheet

Our current range centres on the Ampd 200 and Ampd 400, mobile battery energy storage systems made by Ampd Energy. Every figure here comes from the manufacturer’s IEC brochures and keeps its revision, unit and duration.

Which unit suits a project, and in what configuration, is settled by a technical assessment. Availability for your territory is confirmed in your proposal.

Concept illustrationGeneric enclosure for illustration. Not a depiction of either model.

At a glance

Ampd 200

IEC · Rev 1.3 · 29 April 2026

Nominal output
193kW
214 kVA
Nominal DC energy
215kWh
Usable AC energy is lower
Overload, time-limited
233 kW / 248 kVA for up to 60 seconds
Overload, time-limited
292 kW / 297 kVA for up to 10 seconds
Maximum charging input
205 kW
Supply arrangement
380 to 415 Vac, 3Ph + N + PE
Maximum wet weight
5,500 kg

Ampd 200 specifications and options

Ampd 400

IEC · Rev 1.3 · 29 April 2026

Nominal output
386kW
428 kVA
Nominal DC energy
430kWh
Usable AC energy is lower
Overload, time-limited
466 kW / 496 kVA for up to 60 seconds
Overload, time-limited
585 kW / 595 kVA for up to 10 seconds
Maximum charging input
410 kW
Supply arrangement
380 to 415 Vac, 3Ph + N + PE
Maximum wet weight
9,000 kg

Ampd 400 specifications and options

Source: Ampd 200 IEC brochure, Rev 1.3, dated 29 April 2026; Ampd 400 IEC brochure, Rev 1.3, dated 29 April 2026. Manufacturer-published figures for the IEC variant, not independently tested. Specifications can change, so the current data sheet for your territory is confirmed in a project proposal.

Nominal output is the number to plan around

Each unit has three output ratings. The nominal rating is what it sustains. The two overload ratings are higher but time-limited: one for up to 60 seconds, one for up to 10 seconds.

Overloads matter for motor starting and short lifts. They are not a larger continuous rating, and the brochures do not set out the conditions for repeated overloads, so demanding duty cycles are checked by an engineer.

How kW, kVA and kWh differ

Ampd 200

Nominal output193 kW / 214 kVA
Overload, up to 60 seconds233 kW / 248 kVA
Overload, up to 10 seconds292 kW / 297 kVA

Ampd 400

Nominal output386 kW / 428 kVA
Overload, up to 60 seconds466 kW / 496 kVA
Overload, up to 10 seconds585 kW / 595 kVA
Nominal: the sustained rating Overload: time-limitedBars share one kW scale. Ampd 200 IEC brochure, Rev 1.3, dated 29 April 2026; Ampd 400 IEC brochure, Rev 1.3, dated 29 April 2026.

Full comparison

Standard specification as listed. Optional equipment is shown separately on each product page and is not included unless it is specified in a proposal.

Ampd 200 and Ampd 400 IEC Rev 1.3: full specification comparison
SpecificationAmpd 200IEC · Rev 1.3 · 29 April 2026Ampd 400IEC · Rev 1.3 · 29 April 2026
Output
Nominal output power193 kW / 214 kVA386 kW / 428 kVA
Nominal output current at 380 / 400 / 415 Vac325 / 309 / 298 A650 / 618 / 595 A
Overload output, up to 60 secondsTime-limited rating, not continuous output.233 kW / 248 kVA466 kW / 496 kVA
Overload current, up to 60 seconds, at 380 / 400 / 415 Vac377 / 358 / 345 A754 / 716 / 690 A
Overload output, up to 10 secondsTime-limited rating, not continuous output.292 kW / 297 kVA585 kW / 595 kVA
Overload current, up to 10 seconds, at 380 / 400 / 415 Vac452 / 429 / 414 A904 / 858 / 827 A
Energy storage
Rated nominal DC capacityNominal DC capacity. Usable delivered AC energy is lower and is confirmed per project.215 kWh430 kWh
Battery cell typeCATL lithium iron phosphate (lfp)CATL lithium iron phosphate (lfp)
Rated battery cell lifeCell rating. The brochure states it does not equal warranted cycles.9,000 cycles9,000 cycles
Charging input
Maximum charging powerUnit limit. Actual charging depends on the supply available on site.205 kW410 kW
Maximum charging current at 380 / 400 / 415 Vac312 / 297 / 286 A624 / 593 / 571 A
Electrical
Voltage range380 to 415 Vac (3Ph + N + PE)380 to 415 Vac (3Ph + N + PE)
Frequency, as printed50 / 60 ± 2.5 Hz50 / 60 ± 2.5 Hz
Generator integration
Supported configurationAmpd 200 connected with 1 generatorAmpd 400 connected with 1 generator
Microgrid controller compatibilityComAp or DeepSeaComAp or DeepSea
Recommended maximum generator capacityA recommended maximum, not a minimum or default generator size.350 kVA650 kVA
Mechanical
Ambient operating temperature−30 to +55 °C (derating from 45 °C)−20 to +50 °C (derating from 45 °C)
Dimensions (L × W × H)2.40 × 2.15 × 2.20 m3.0 × 2.3 × 2.4 m
Maximum wet weightActual weight depends on the optional features fitted.5,500 kg9,000 kg
Ingress protection: batteries and HVACIP67IP67
Ingress protection: container enclosureIP55IP54
Corrosion protection (standard)C3C3
Other
Fire suppression systemAerosol agentAerosol agent
Thermal management and coolantLiquid cooled, ethylene glycolLiquid cooled, ethylene glycol
ConnectivityCellular 4GCellular 4G
Warranty durationDuration only. Warranty terms and any warranted throughput are confirmed in a proposal.5 years5 years